Car parks extraction
Underground Car Park Ventilation — Jet Fan Systems, F400 Smoke Extraction and CO Sensors
Underground car parks are among Romania's most regulated spaces: normative NP 127:2009, complemented by NP 24-2022 and P118-1:2025, mandatorily requires mechanical forced ventilation with two distinct functions — normal anti-CO ventilation (daily operation) and emergency smoke extraction in case of fire at 300–400°C for 120 minutes.
Anti-CO ventilation: carbon monoxide emitted by combustion engines accumulates rapidly in enclosed spaces. STAS 12574 requires maximum 50 ppm CO continuous and 100 ppm short-term. CO sensors on ventilation.ro (HVAC Control category) automatically activate the ventilation system when the threshold is exceeded.
The Jet Fan system — the modern ductwork-free solution: ceiling-mounted impulse fans create through the Coandă effect an organised flow transporting CO and smoke to final extraction outlets, completely eliminating the need for a distribution duct network. Advantages over the traditional duct system: 30–40% lower initial investment, faster installation, simpler maintenance.
Axial Jet Fans JF 300 T2/T4 on ventilation.ro with integrated acoustic attenuators, F300/120 certified per EN 12101-3.
Low Profile centrifugal Jet Fans for car parks with clear height below 2.2 m. F400/120 final extraction fans for mounting outside the hazardous zone.
Important: Jet Fan system sizing must be validated through a mandatory CFD study (SR CEN/TR 12101-5) — the only method demonstrating smoke evacuation compliance that ISU accepts for approval.
BOX BSTB 355 F400 0,75kW
BOX BSTB 355 F400 0,75kW
Pre-order
BOX BSTB 400 F400 1,5kW
BOX BSTB 400 F400 1,5kW
Pre-order
BOX BSTB 450 F400 2,2kW
BOX BSTB 450 F400 2,2kW
Pre-order
BOX BSTB 500 F400 4kW
BOX BSTB 500 F400 4kW
Pre-order
BOX BSTB 560 F400 5,5kW
BOX BSTB 560 F400 5,5kW
Pre-order
BVFC 10/10 1,1kW
BVFC 10/10 1,1kW
Pre-order
BVFC 12/12 1,5kW
BVFC 12/12 1,5kW
Pre-order
BVFC 15/15 2,2kW
BVFC 15/15 2,2kW
Pre-order
BVFC 18/18 5,5kW
BVFC 18/18 5,5kW
Pre-order
BVFC 9/9 0,37 kW
BVFC 9/9 0.37kW
Pre-order
Centrifugal roof fans - RDM 3E-2528-4W-07
RDM 3E-2528-4W-07
Roof centrifugal fan
Pre-order
Centrifugal roof fans - RDM 3E-2531-4W-07
RDM 3E-2531-4W-07
Roof centrifugal fan
Pre-order
Centrifugal roof fans - RDM 3E-3535-4W-08
RDM 3E-3535-4W-08
Roof centrifugal fan
In stock
Centrifugal roof fans - RDM 3E-3545-43-11
RDM 3E-3545-43-11
Roof centrifugal fan
Pre-order
Centrifugal roof fans - RDM 3E-4550-43-14
RDM 3E-4550-43-14
Roof centrifugal fan
Pre-order
Centrifugal roof fans - RDM 3E-4556-43-17
RDM 3E-4556-43-17
Roof centrifugal fan
Pre-order
Centrifugal roof fans - RDM 3E-4556-63-13
RDM 3E-4556-63-13
Roof centrifugal fan
Pre-order
Centrifugal roof fans - RDM 3E-5663-63-16
RDM 3E-5663-63-16
Roof centrifugal fan
Pre-order
JET fan - JFC 315 T2 RE 0,55 kW
The JFC F400 models are composed of an axial fan and two silencers.
Pre-order
JET fan - JFC 315 T2 UN 0,55 kW
JFC 315 T2 UN F400
The JFC F400 models are composed of an axial fan and two silencers.
Pre-order
JET fan - JFC 315/H T2 UN 1,1 kW
The JFC F400 models are composed of an axial fan and two silencers.
Pre-order
JET fan - JFC 355 T2 RE 0,55 kW
The JFC F400 models are composed of an axial fan and two silencers.
Pre-order
JET fan - JFC 355 T2 UN 0,55 kW
The JFC F400 models are composed of an axial fan and two silencers.
Pre-order
JET fan - JFC 355/H T2 RE 1,1 kW
Applications
Pre-order
JET fan - JFC 400 T2 RE 1,1 kW
The JFC F400 models are composed of an axial fan and two silencers.
Pre-order
JET fan - JFC 400 T2 UN 1,1 kW
The JFC F400 models are composed of an axial fan and two silencers.
Pre-order
JET fans - JF 300 T2 RE F300
JF 300 T2 RE F300
Pre-order
JET fans - JF 300 T2 UN CONFORT
Casals JF 300 T2 UN CONFORT — unidirectional axial jet fan designed for polluted air (CO, CO₂) and accidental fire smoke evacuation in underground car parks and large spaces, in compliance with normative NP 24-2022.
Maximum airflow 4,500 m³/h, thrust force 26 N, three-phase motor 0.55 kW, 2,780 rpm, current 1.36A / 400V, protection IP55, insulation Class F, maximum operating temperature 60°C.
Composed of an axial fan with galvanised steel casing flanked by 2 mineral wool silencers — significant acoustic attenuation versus non-silenced jet fans.
The UN (unidirectional) variant is equipped with an inlet protection guard and an outlet deflector that directs the air jet away from the ceiling and obstacles, sweeping the complete air volume towards the extraction point.
Total length: 2,415 mm. Weight: 60 kg
Pre-order
JET fans - JF 300 T2 UN F300
JF 300 T2 UN F300
Pre-order
JET fans - JF 300 T2/T4 RE F300
JF 300 T2/T4 RE F300
Pre-order
JET fans - JF 300 T2/T4 UN CONFORT
JF 300 T2/T4 UN CONFORT
Pre-order
JET fans - JF 300 T2/T4 UN F300
JF 300 T2/T4 UN F300
Pre-order
JET fans - JF 400 T2 RE F300
JF 400 T2 RE F300
Pre-order
JET fans - JF 400 T2 UN CONFORT
Pre-order
JET fans - JF 400 T2 UN F300
JF 400 T2 UN F300
Pre-order
JET fans - JF 400 T2/T4 RE F300
JF 400 T2/T4 RE F300
Pre-order
JET fans - JF 400 T2/T4 UN CONFORT
Pre-order
JET fans - JF 400 T2/T4 UN F300
JF 400 T2/T4 UN F300
Pre-order
Pre-order
JET fans - JFC 315 T2 UN CONFORT
Pre-order
Sales