Cinemas
Cinema Hall and Multiplex Ventilation — Products for Acoustic Comfort and Clean Air
The cinema auditorium is one of the most demanding ventilation spaces: hundreds of people in windowless spaces, projection and sound equipment with significant heat emissions, extreme acoustic requirements and a permanent need for fresh air without disturbing draughts or noise.
Mandatory airflow requirements: minimum 30 m³/h per person per Romanian hygiene regulations. A 400-seat hall requires minimum 12,000 m³/h fresh air — impossible to ensure through natural ventilation. EC motor fans with CO₂ sensor control (VAV — Variable Air Volume systems) automatically optimise airflow based on actual occupancy, reducing energy consumption by 40–50% versus constant airflow operation.
Acoustic comfort is critical — the audience hears the fan if it produces more than 30–35 dB(A). DWDI/RDP EC incorporated fans or soundproofed BOX BD PLUS, operated at partial speeds via EC motor, generate 6–12 dB(A) less noise than fixed-speed AC equivalents.
Smoke extraction is mandatory per P118-1:2025 for significant-capacity halls — F300/120 certified fans with automatic actuation at fire panel signal.
Centrifugal roof fans - RDA 21-2225-2E
RDA 21-2225-2E
Roof centrifugal fan
Pre-order
Centrifugal roof fans - RDM 3E-2528-4W-07
RDM 3E-2528-4W-07
Roof centrifugal fan
Pre-order
Centrifugal roof fans - RDM 3E-2531-4W-07
RDM 3E-2531-4W-07
Roof centrifugal fan
Pre-order
Centrifugal roof fans - RDM 3E-3535-4W-08
RDM 3E-3535-4W-08
Roof centrifugal fan
In stock
Centrifugal roof fans - RDM 3E-3545-43-11
RDM 3E-3545-43-11
Roof centrifugal fan
Pre-order
Centrifugal roof fans - RDM 3E-4550-43-14
RDM 3E-4550-43-14
Roof centrifugal fan
Pre-order
Centrifugal roof fans - RDM 3E-4556-43-17
RDM 3E-4556-43-17
Roof centrifugal fan
Pre-order
Centrifugal roof fans - RDM 3E-4556-63-13
RDM 3E-4556-63-13
Roof centrifugal fan
Pre-order
Centrifugal roof fans - RDM 3E-5663-63-16
RDM 3E-5663-63-16
Roof centrifugal fan
Pre-order
PureAir Room Air Purifier
The PureAir Room is an advanced multistage air cleaning system which removes these harmful particles and neutralises bad smells, purifying the air you and your family breathe for a fresher and healthier indoor environment.
Clean Air Delivery Rate (CADR): 260m3 /h
Coverage up to: 30m2
• Advanced 6 stage filtration system
• Air quality display
• Portable
• Suitable for any habitable room
• Filter replacement reminder
• Timer setting
• 3 speeds
• Sleep mode
• Auto mode
In stock
PureAir Room X Purificator de aer cu App Control
App controlled advanced multi-stage air cleaning system to provide adequate ventilation with fresh clean air to dilute the pollutants.
Removes theharmful particles and neutralises bad smells, purifying the air you and your family breathe for a fresher and healthier indoor environment.
Clean Air Delivery Rate (CADR): 260m3 /h
Coverage up to: 30m2
• Advanced 6 stage filtration system
• Air quality display
• Portable
• Suitable for any habitable room
• Filter replacement reminder
• Timer setting
• 3 speeds
• Sleep mode
• Auto mode
Functions for Vent-Axia PureAir Room X:
In stock
Smoke Extract Roof Fan - DHUMAT 315 T2 1,1kW F400
DHUMAT 315 T2 1,1kW F400
Pre-order
Smoke Extract Roof Fan - DHUMAT 315 T4 0,25kW F400
DHUMAT 315 T4 0,25kW F400
Pre-order
Smoke Extract Roof Fan - DHUMAT 355 T2 2,2kW F400
DHUMAT 315 T2 2,2kW F400
Pre-order
Smoke Extract Roof Fan - DHUMAT 355 T4 0,55kW F400
DHUMAT 355 T4 0,55kW F400
Pre-order
Smoke Extract Roof Fan - DHUMAT 400 T4 0,75kW F400
DHUMAT 400 T4 0,75kW F400
Pre-order
Smoke Extract Roof Fan - DHUMAT 450 T4 1,1kW F400
DHUMAT 450 T4 1,1kW F400
Pre-order
Smoke Extract Roof Fan - DHUMAT 500 T4 1,5kW F400
DHUMAT 500 T4 1,5kW F400
Pre-order
Smoke Extract Roof Fan - DHUMAT 560 T4 3kW F400
DHUMAT 560 T4 3kW F400
Pre-order
Smoke Extract Roof Fan - DHUMAT 630 T4 4kW F400
DHUMAT 630 T4 4kW F400
Pre-order
Smoke Extract Roof Fan - HMF 45 T4 0,75kW
HMF 45 T4 0.75kW
Pre-order
Smoke Extract Roof Fan - HMF 50 T4 0,75 kW
HMF 45 T4 0.75kW
Pre-order
Smoke Extract Roof Fan - HMF 56 T4 1,1kW
HMF 56 T4 1.1kW
Pre-order
Smoke Extract Roof Fan - HMF 63 T4 1,1kW
HMF 63 T4 1.1kW
Pre-order
Smoke Extract Roof Fan - HMF 80 T4 2,2kW
HMF 80 T4 2,2kW
Pre-order
Smoke Extract Roof Fan - IGNÉO 311 T4 0,55kW
IGNÉO 311 T4 0,55kW
Pre-order
Smoke Extract Roof Fan - IGNÉO 351 T4 0,55kW
IGNÉO 351 T4 0,55kW
Pre-order
Smoke Extract Roof Fan - IGNÉO 401 T4 0,55kW
IGNÉO 401 T4 0,55kW
Pre-order
Smoke Extract Roof Fan - IGNÉO 451 T4 1,1kW
IGNÉO 451 T4 1,1kW
Pre-order
Smoke Extract Roof Fan - IGNÉO 501 T4 1,5kW
IGNÉO 501 T4 1,5kW
Pre-order
Smoke Extract Roof Fan - IGNÉO 501 T6 0,55kW
IGNÉO 501 T6 0,55kW
Pre-order
Smoke Extract Roof Fan - IGNÉO 561 T4 3kW
IGNÉO 561 T4 3kW
Pre-order
Smoke Extract Roof Fan - IGNÉO 561 T6 0,75kW
IGNÉO 561 T6 0,75kW
Pre-order
Smoke Extract Roof Fan - IGNÉO 631 T4 5,5kW
IGNÉO 631 T4 5,5kW
Pre-order
Smoke Extract Roof Fan - IGNÉO 711 T4 7,5kW
IGNÉO 711 T4 7,5kW
Pre-order
Smoke Extract Roof Fan - RDM 56-2528-2W-11
Smoke Extract Roof Fan
Pre-order
Smoke Extract Roof Fan - RDM 56-2528-4W-10
Smoke Extract Roof Fan
Pre-order
Smoke Extract Roof Fan - RDM 56-2531-4W-10
RDM 56-2531-4W-10
Pre-order
Smoke Extract Roof Fan - RDM 56-3535-4W-10
RDM 56-3535-4W-10
Pre-order
Smoke Extract Roof Fan - RDM 56-3540-4W-10
RDM 56-3540-4W-10
Pre-order
Smoke Extract Roof Fan - RDM 56-3545-4W-13
RDM 56-3545-4W-13
Pre-order
Smoke Extract Roof Fan - RDM 56-3545-6W-10
RDM 56-3545-6W-10
Pre-order
Smoke Extract Roof Fan - RDM 56-4550-4W-16
RDM 56-4550-4W-16
Pre-order
Smoke Extract Roof Fan - RDM 56-4556-4W-17
RDM 56-4556-4W-17
Pre-order
Smoke Extract Roof Fan - RDM 56-5663-4W-23
RDM 56-3545-4W-13
Pre-order
Variable speed exhaust kit 3990 m³/h — complete system with DD 9/9 fan in acoustic plenum box, ductwork and grilles
Variable speed exhaust kit 3990 m³/h — complete, installation-ready system.
Includes double-width double-inlet centrifugal fan DD 9/9 M96R pre-mounted in acoustic plenum box (aluminium profile structure + Class A1 polyurethane insulation), 10 m flexible aluminium ductwork Ø200 mm, 4 circular anodised aluminium extract grilles with flange for direct duct connection, gravity backdraft damper and electronic speed controller with ON/OFF switch. Single-phase motor 230V / 50Hz, IP54, Class F insulation.
Maximum operating temperature: 50°C.
Ideal for commercial spaces, residential applications, workshops and laboratories.
In stock
Sales