Welcome to our store!

Fans selection

PRODUCER

Motor type

Heating capacity

  • kW
  • kW
  • kW
  • kW
  • kW
  • kW
  • kW
  • kW
  • kW

Differential controllers (VAV controll)

Constant pressure, air volume flow or air velocity?
This differential pressure controller controls EC fans or AC fan speed controllers. It maintains the differential pressure [Pa] constant at the set point. The operating range is -125 to +125 Pa. It is also possible to control fan speed based on air volume flow [m³/hr] or air velocity [m/s]. To control air volume flow based on the K-factor of the fan, use the optional connection set type 
PSET-PVC-200 or PSET-QF-200. This connection set can also be used to control differential pressure. To control air volume flow based on the duct cross section [cm²] or air velocity [m/s], use the optional connection set type PSET-PTS-200 or PSET-PTL-200. The setpoint can be adjusted via Modbus RTU.
Visual indication
This pressure controller offers a clear, visual indication of the differential pressure level via the green, yellow and red LED. The green LED indicates that the pressure level is within range. When the pressure level enters the alert range, the yellow LED lights up. Red means: differential pressure out of range. The LEDs can also visualise the status of the air volume flow or air velocity. The second green LED indicates the sensor status. It is activated when power supply and Modbus RTU communication are enabled. 
How does it work?
This pressure controller has one analogue output. This output controls EC fans or AC fan speed controllers based on the measured differential pressure, air volume flow or air velocity. The fan speed is controlled to maintain the measured value constant at the setpoint. The setpoint can be adjusted via Modbus RTU. To make this controller compatible with most EC fans and AC fan speed controllers, the output type can be adjusted via Modbus RTU: 0-10 VDC / 0-20 mA / 0-100 % PWM. To match the reaction time of the fan to the application, P and I factors can be adjusted via Modbus RTU.
4-wire connection
The supply voltage, the analogue output and Modbus RTU communication can be connected via the cage clamp terminal block. They eliminate the need for routine maintenance and guarantee a reliable contact for solid or stranded wires. The supply voltage is 24 VDC. The ground terminals of the power supply (V-) and output (GND) are galvanically separated. This means that a 
4-wire cable is required to connect this sensor. Most 24 VDC power supplies offer protection against short circuit, overload and overvoltage. A 24 VDC supply voltage increases the safety and reliability of your installation
High quality
The enclosure is made of high-quality r-ABS VO (UL94) plastic. This material is heat resistant, very tough and offers good protection against impacts. The pressure connection nozzles are made from Aluminium. The sensor enclosure offers an IP65 protection against ingress of dirt and water. This pressure controller can be wall-mounted.
Maintain overpressure in staircases
A typical application for differential pressure controllers with this range is to maintain an underpressure or overpressure in staircases or cleanrooms.
E.g. by creating a constant overpressure in the staircase, it remains smoke-free in case of fire.
Filters
«1»
  • DPSPF-1K0 -2

    DPSPF-1K0 -2

    Price excl. tax:€24148
    Price inc. tax:€28736
  • DPSPF-LP

    DPSPF-LP

    Price excl. tax:€28485
    Price inc. tax:€33897
  • DPSPM-LP

    DPSPM-LP

    Price excl. tax:€26084
    Price inc. tax:€31039
Page 1 of 1
«1»