REINTAIR® WARRIOR L 600 EC — industrial Plug & Play air purifier 600 m³/h, HEPA H14 + UV-C + TiO2 photocatalysis, for spaces up to 90 m²
Pre-order
Casals REINTAIR® WARRIOR L 600 EC — the high-capacity variant of the REINTAIR WARRIOR industrial purifier, manufactured in Spain.
Maximum airflow 600 m³/h — double the S variant — suitable for spaces of up to 90 m² at 2.5m ceiling height. 4-stage filtration system: 2× ISO Coarse 65% pre-filter (G4) + 2× HEPA H14 (99.995% efficiency) + PHOTOCATALYSIS-UVC Tower with UV-C lamp and titanium dioxide TiO₂ chemically neutralising bacteria, viruses and VOCs.
Low consumption EC motor, 230V Plug & Play — no installation, no installer required.
Soundproofed 30mm extruded aluminium profile structure with 25mm class A1 rockwool insulation, 4 braked wheels, control panel with autonomous mode, 0–10 flow adjustment, night mode and filter clogging alarm.
Quick Buy
-
RENTAIRVARIORL600EC
-
43.000 Kgs
WARRIOR L vs WARRIOR S — when to choose the larger variant
| WARRIOR S 300 EC | WARRIOR L 600 EC | |
|---|---|---|
| Maximum airflow | 300 m³/h | 600 m³/h |
| Recommended area | up to 45 m² | up to 90 m² |
| Manufacturer code | REIN2-300ECW | REIN2-600ECW |
| Filtration | 4-stage G4 + HEPA H14 | 4-stage G4 + HEPA H14 |
| UV-C + TiO₂ photocatalysis | ✅ | ✅ |
| Braked wheels | ✅ | ✅ |
| Plug & Play | ✅ | ✅ |
Choose WARRIOR L when:
- Space exceeds 45 m²
- More air changes per hour are required in the same space
- A single unit must cover an open plan or large room
- High-density public spaces: restaurants, classrooms, conference rooms
Choose WARRIOR S (or 2× S) when:
- Space is under 45 m²
- Redundancy is needed — two S units cover 90 m² but operate independently in two separate rooms
Typical applications for the L 600 m³/h variant
Office open plan 60–90 m² — 3+ complete air changes per hour. Autonomous mode adjusts airflow based on actual occupancy.
Classroom / University hall 50–80 m² — 25–30 students generate intense CO₂ and biological particles. WARRIOR L provides required airflow without disruptive noise. Night mode automatically stops the unit outside school hours.
Conference room 60–90 m² — variable occupancy managed automatically by autonomous mode.
Clinic waiting room / Hospital 50–90 m² — critical application. HEPA H14 + UV-C/TiO₂ photocatalysis significantly reduce viral and bacterial load in recirculated air. Unit moves on wheels during cleaning or low-traffic periods.
Restaurant dining room 70–90 m² — safety supplement in large restaurants. Complements mechanical ventilation with active filtration of recirculated air.
Pharmacy / Laboratory 50–80 m² — VOCs from pharmaceutical preparations, detergents and disinfectants chemically decomposed by activated carbon + HEPA H14 + TiO₂ photocatalysis.
Full technical specifications
| Specification | Value |
|---|---|
| Model | REINTAIR® WARRIOR L 600 EC |
| Manufacturer code | REIN2-600ECW |
| Maximum airflow | 600 m³/h |
| Recommended area | up to 90 m² (H=2.5m) |
| Filtration stages | 4 |
| Pre-filters | 2× ISO Coarse 65% (G4) |
| Main filters | 2× HEPA H14 (99.995%) |
| Additional system | PHOTOCATALYSIS-UVC Tower (TiO₂ + UV-C) |
| Motor | EC external rotor, self-cleaning impeller |
| Voltage | 230V / 50Hz — Plug & Play |
| Motor protection | IP44 |
| Insulation class | B |
| Structure | 30mm soundproofed extruded aluminium profile |
| Insulation | 25mm rockwool class A1, 90 kg/m³ |
| Fire reaction | M0 |
| Mobility | 4 braked wheels |
| Control panel | On/Off, Auto, 0–10 flow, night mode, filter alarm |
| Installation | Plug & Play — no installation required |
| Colour | RAL 9006 (silver grey) |
| Manufactured | Spain (Casals) |
| Warranty | 2 years |
FAQ — EN
Two WARRIOR S units or one WARRIOR L for 90 m²? Both options cover 90 m². Two S units provide redundancy — if one fails, the other continues — and allow independent use in two 45 m² rooms. One L unit is simpler to manage and more economical at purchase. Choose L for a single large space. Choose 2× S for two separate spaces or redundancy requirement.
Can it operate alongside an existing mechanical ventilation system? Yes — REINTAIR WARRIOR complements mechanical ventilation, it does not replace it. Mechanical ventilation supplies fresh air and removes CO₂. WARRIOR filters and disinfects recirculated room air. The two systems are complementary.
Is it suitable for classrooms? Yes — 600 m³/h in a 60 m² classroom (150 m³) means 4 complete air changes per hour. Combined with mechanical ventilation supplying fresh air, WARRIOR L reduces biological particle concentration and helps maintain CO₂ below 1,000 ppm. Night mode automatically stops the unit outside school hours.
How often are filters replaced under intensive use? Automatic alarm on control panel signals clogging. Under intensive use (8+ hours/day in high-traffic spaces): G4 pre-filters every 2–3 months, HEPA H14 filters every 8–12 months. Access via quick-release side panels without tools.
-
Air flow:600 m3/h
-
Motor type:EC motor
-
Voltage:230 V - 50 Hz
| File | Info |
|---|---|
REINTAIR-WARRIOR-L-600-EC
|
[PDF, 456.71 KB] |