The Nicotra Gebhardt DDM 12/12 M7A2 is a double-inlet centrifugal fan with forward-curved blades and direct drive. The impeller is mounted directly on the motor, so there are no belts and no transmission losses.

  • Airflow: maximum ~11,000 m³/h; about 10,000 m³/h at 200 Pa and 8,800 m³/h at 400 Pa
  • Pressure: static pressure up to ~700 Pa
  • Motor: three-phase 400 V / 50 Hz, 2.2 kW, 4-pole, 1,400 rpm, 2 speeds (Δ/Y)
  • Protection: IP54, Class F insulation, thermal protection
  • Construction: galvanised steel casing and impeller, dynamically balanced to ISO 1940, supplied with a fitted discharge flange
  • Operation: maximum air temperature 40 °C; weight 59 kg

Performance tested to AMCA 210 / ISO 5801. Delivered from stock.

  • Air flow:
    12000 m3/h
  • Motor type:
    AC motor
  • Motor power:
    2.2 kW
  • Voltage:
    400 V - 50 Hz
  • Motor speed:
    4 POLE
Add to wishlist
Credit Calculator

Credit calculator

Centrifugal fan DDM 12/12 M7A2 3F 4P 2V
Please select credit institution
Product price: €1.326,00
Extraction of information from credit institutions
Предоставената таблица е с информационна цел. Добавете продукта в количката си с бутона "Добави в количката" и при поръчка ще можете да изберете броя вноски на кредита.
Acest tabel are caracter informativ. Adăugați produsul în coșul de cumpărături unde veți putea selecta detaliile cererii de creditare.
Предоставената таблица е с информационна цел. Добавете продукта в количката си с бутона "Добави в количката" и при поръчка ще можете да изберете броя вноски на кредита.
Предоставената таблица е с информационна цел. Добавете продукта в количката си с бутона "Добави в количката" и при поръчка ще можете да изберете броя вноски на кредита.
Предоставената таблица е с информационна цел. Добавете продукта в количката си с бутона "Добави в количката" и при поръчка ще можете да изберете броя вноски на кредита.
Предоставената таблица е с информационна цел. Добавете продукта в количката си с бутона "Добави в количката" и при поръчка ще можете да изберете броя вноски на кредита.

Когато плащате с NewPay, всъщност NewPay плаща поръчката Ви вместо Вас. Вие я получавате и разполагате с три начина да я платите към тях:

  • Отложено до 30 дни от момента на изпращане на поръчката без оскъпяване. За покупки на стойност до 400 лв. / €204,52
  • Плащане на 4 вноски. Заплащате 20% от стойността на поръчката си на момента с карта. Останалата сума се разделя на 3 равни месечни вноски без оскъпяване. За покупки на стойност до 1000 лв. / €511.31
  • Плащане на 6 вноски. Стойността на поръчката се разпределя в 6 равни месечни вноски с оскъпяване. За покупки на стойност до 2000 лв. / €1022.61

Quick Buy

Just 4 fields to fill in
We will contact you to finalize the order
  • FN02123
  • 59.000 Kgs

Industrial-hall airflow from a compact fan

The DDM 12/12 M7A2 moves almost 12,000 m³/h through a casing of only 490 × 521 × 451 mm. On a system with a filter, a heating coil and ductwork, it keeps around 9,000–10,000 m³/h. It is the right fan for:

  • high-airflow air handling units

  • air heaters and heated fresh air units for industrial halls

  • ventilation boxes for commercial and industrial spaces

The double-inlet impeller draws air from both sides at once. This gives it an airflow that a single-inlet fan reaches only with a much larger casing.

Measured performance

Manufacturer’s curve at maximum speed (400 V, delta connection):

  • 0 Pa, free discharge: approx. 12,000 m³/h

  • 200 Pa: approx. 10,000 m³/h

  • 400 Pa: approx. 8,800 m³/h

  • 600 Pa: approx. 7,500 m³/h

  • Maximum static pressure: approx. 700 Pa

On a typical installation (filter, heating coil, medium-length ductwork, 200–400 Pa), the fan delivers 9,000–10,000 m³/h. At high resistance, airflow drops gradually, not suddenly.

Note: the manufacturer advises against operating the fan in the area to the left of the curve (below about 5,000 m³/h at full speed), where operation becomes unstable. If you need less airflow, reduce the speed.

Noise: sound power level LWA is 85–95 dB, depending on the operating point. For occupied spaces, install it in an acoustic box and use duct silencers.

Two speeds, by connection

The three-phase motor has two speeds:

  • Delta (Δ): maximum speed, up to ~12,000 m³/h

  • Star (Y): reduced speed, about 8,000 m³/h at free discharge, with lower noise and energy use

For continuous control, the manufacturer allows a transformer, a TRIAC controller or a frequency inverter. Size the controller for the motor’s maximum current of 9.7 A.

Construction

  • Casing: galvanised steel sheet, seamed

  • Impeller: galvanised steel, forward-curved blades, dynamically balanced to ISO 1940

  • Motor: 2.2 kW, IP54, Class F, external thermal protection (thermal contacts at the terminal box)

  • Discharge flange: factory-fitted

  • Installation type (ISO 5801): B, meaning free inlet and ducted outlet

  • Casing, impeller and motor are all made by Nicotra Gebhardt

Where you can use it

Heated fresh air for industrial halls. With a BAC 120 (120 kW, 11,000 m³/h) or BAC 90 hot water heating coil and a G4 filter, you build a fresh air unit for workshops, warehouses and sports halls of 1,000–2,000 m².

High-airflow air handling units and heat recovery units for offices, shops, hotels and event halls.

Acoustic ventilation boxes, such as the BOX PLUS 12/12, for ducted extraction or supply.

General industrial ventilation: production halls, warehouses, large commercial spaces.

When it is NOT suitable

  • Hot, greasy air above 40 °C, such as from kitchen hoods: choose a CF HP fan with an external motor, designed for air up to 150 °C.

  • Low airflow, below 5,000 m³/h: choose a smaller model, such as the DD 9/9 M96R (3,990 m³/h, single-phase) or the OMNIBOX DD 10/10 (7,000 m³/h).

Recommended installation

  • On the discharge: a gravity backdraft grille, sized to the flange

  • Between the fan and the ductwork: flexible anti-vibration connectors

  • Next to the fan: a maintenance isolator switch, e.g. EME5-20-4111

  • On the inlet: a G4 filter, if air is drawn from outside

  • To balance the system: a damper in the ductwork

Dimensions (mm)

  • Overall length: 490.5

  • Overall height: 521

  • Overall width, with terminal box: 451

  • Casing width: 395

Technical specifications​

  • Type: double-inlet centrifugal (DWDI), forward-curved blades, direct drive

  • Maximum airflow: approx. 11,000 m³/h

  • Airflow at 200 Pa: approx. 10,000 m³/h

  • Airflow at 400 Pa: approx. 8,800 m³/h

  • Maximum static pressure: approx. 700 Pa

  • Motor: 2.2 kW, three-phase, 4-pole

  • Power supply: 400 V / 50 Hz

  • Connection: Δ/Y, 2 speeds

  • Speed: 1,400 rpm

  • Maximum current: 9.7 A

  • Maximum power consumption: 5,780 W

  • Speed control: transformer, TRIAC or frequency inverter

  • Protection: IP54

  • Insulation: Class F, external thermal protection

  • Maximum air temperature: 40 °C

  • Noise (sound power LWA): 85–95 dB, depending on the operating point

  • Casing and impeller: galvanised steel, balanced to ISO 1940

  • Dimensions (L × H × W): 490.5 × 521 × 451 mm

  • Weight: 59 kg

  • Supplied with: fitted discharge flange

  • Testing: AMCA 210 / ISO 5801, installation type B

👉 BOX PLUS 12/12 acoustic box
👉 BAC 120 heating coil
📞 +40 722 667 238 — free consultancy

  • Air flow:
    12000 m3/h
  • Impeller size:
    12/12
  • Motor type:
    AC motor
  • Motor power:
    2.2
    kW
  • Voltage:
    400 V - 50 Hz
  • Motor speed:
    4 POLE
  • Mounting:
    Hood inside
  • Plenum box:
    Yes
File Info
Nicotra Gebhardt SPA AMCA 2019 2022 [PDF, 734.83 KB]
REGAL_BELOIT_ITALY_SPA_9001-ENGL [PDF, 747.69 KB]
12-12 [PDF, 389.06 KB]

Duct pressure drop calculator

💨 Calculator pierderi de presiune în tubulaturi

Chat WhatsApp
Cu ce te putem ajuta astazi?