Outside the hazardous area
Smoke extract fans — outside hazardous area, motor protected in clean air
Fans for mounting outside the hazardous area are smoke extraction equipment in which the electric motor is located and operates in clean air — outside the smoke stream — while the rotor extracts hot gases from the fire zone through ductwork. An extended shaft or a separate motor cooling duct ensures thermal and chemical separation of the motor from the smoke environment.
This construction offers important advantages over inside hazardous area mounting: the motor is not exposed to extreme temperatures, corrosive smoke and combustion gases, which reduces motor construction requirements and sometimes allows the use of standard AC motors (where the installation ensures sufficient distance from the smoke). Certification remains mandatory to EN 12101-3, but a wider range of models is available.
Preferred in commercial and office buildings where plant rooms allow locating the fan away from the protected zone, shopping centres with layouts permitting moderate-length smoke ducts, hotels and apartment buildings with smoke control systems on corridors and stairwells, hospitals and any building where the designer can ensure motor placement outside the classified smoke zone.
From the designer's perspective, the choice between "inside" and "outside hazardous area" is made at the design stage — after smoke duct routes are established and fan placement is determined from architectural considerations. Both solutions are accepted by EN 12101 and the applicable building regulations, subject to appropriate certification.
Documents to verify: identical to the "inside hazardous area" category — notified body certificate, EN 12101-3 performance declaration, CE marking, F300/F400 classification and duration (60/120 minutes).
👉 Smoke extract fans inside hazardous area — when motor cannot be separated from smoke 👉 ATEX roof fans — for rooftops with explosion risk
BOX BSTB 355 F400 0,75kW
BOX BSTB 355 F400 0,75kW
Pre-order
BOX BSTB 400 F400 1,5kW
BOX BSTB 400 F400 1,5kW
Pre-order
BOX BSTB 450 F400 2,2kW
BOX BSTB 450 F400 2,2kW
Pre-order
BOX BSTB 500 F400 4kW
BOX BSTB 500 F400 4kW
Pre-order
BOX BSTB 560 F400 5,5kW
BOX BSTB 560 F400 5,5kW
Pre-order
BVFC 10/10 1,1kW
BVFC 10/10 1,1kW
Pre-order
BVFC 12/12 1,5kW
BVFC 12/12 1,5kW
Pre-order
BVFC 15/15 2,2kW
BVFC 15/15 2,2kW
Pre-order
BVFC 18/18 5,5kW
BVFC 18/18 5,5kW
Pre-order
BVFC 9/9 0,37 kW
BVFC 9/9 0.37kW
Pre-order
ROOF FAN ABS COWL 400ºC-2h - CTH3 315 M4 0,25kW
CTH3 315 M4 0,25kW
Roof fan, ABS COWL 400ºC-2h
Pre-order
ROOF FAN ABS COWL 400ºC-2h - CTH3 315 T4 0,25kW
CTH3 315 T4 0,25kW
Ventilator tip turela rezistent la foc 400ºC-2h
Pre-order
ROOF FAN, ABS COWL 400ºC-2h - CTH-A3 710 T6 2,2kW F400
CTH3-A 710 T6 2,2kW
ROOF FAN, ABS COWL 400ºC-2h
Pre-order
ROOF FAN, ABS COWL 400ºC-2h - CTH-A3 800 T6 4kW F400
CTH3-A 800 T6 4kW
ROOF FAN, ABS COWL 400ºC-2h
Pre-order
ROOF FAN, ABS COWL 400ºC-2h - CTH-A3 900 T6 11kW F400
CTH3-A 900 T6 11kW
ROOF FAN, ABS COWL 400ºC-2h
Pre-order
ROOF FAN, ABS COWL 400ºC-2h - CTH3 710 T6 2,2kW
CTH3 710 T6 2,2kW
Pre-order
ROOF FAN, ABS COWL 400ºC-2h - CTH3 800 T6 4kW
CTH3 800 T6 4kW
ROOF FAN, ABS COWL 400ºC-2h
Pre-order
Smoke Extract Roof Fan - DHUMAT 315 T2 1,1kW F400
DHUMAT 315 T2 1,1kW F400
Pre-order
Smoke Extract Roof Fan - DHUMAT 315 T4 0,25kW F400
DHUMAT 315 T4 0,25kW F400
Pre-order
Smoke Extract Roof Fan - DHUMAT 355 T2 2,2kW F400
DHUMAT 315 T2 2,2kW F400
Pre-order
Smoke Extract Roof Fan - DHUMAT 355 T4 0,55kW F400
DHUMAT 355 T4 0,55kW F400
Pre-order
Smoke Extract Roof Fan - DHUMAT 400 T4 0,75kW F400
DHUMAT 400 T4 0,75kW F400
Pre-order
Smoke Extract Roof Fan - DHUMAT 450 T4 1,1kW F400
DHUMAT 450 T4 1,1kW F400
Pre-order
Smoke Extract Roof Fan - DHUMAT 500 T4 1,5kW F400
DHUMAT 500 T4 1,5kW F400
Pre-order
Smoke Extract Roof Fan - DHUMAT 560 T4 3kW F400
DHUMAT 560 T4 3kW F400
Pre-order
Smoke Extract Roof Fan - DHUMAT 630 T4 4kW F400
DHUMAT 630 T4 4kW F400
Pre-order
Smoke Extract Roof Fan - RDM 56-2528-2W-11
Smoke Extract Roof Fan
Pre-order
Smoke Extract Roof Fan - RDM 56-2528-4W-10
Smoke Extract Roof Fan
Pre-order
Smoke Extract Roof Fan - RDM 56-2531-4W-10
RDM 56-2531-4W-10
Pre-order
Smoke Extract Roof Fan - RDM 56-3535-4W-10
RDM 56-3535-4W-10
Pre-order
Smoke Extract Roof Fan - RDM 56-3540-4W-10
RDM 56-3540-4W-10
Pre-order
Smoke Extract Roof Fan - RDM 56-3545-4W-13
RDM 56-3545-4W-13
Pre-order
Smoke Extract Roof Fan - RDM 56-3545-6W-10
RDM 56-3545-6W-10
Pre-order
Smoke Extract Roof Fan - RDM 56-4550-4W-16
RDM 56-4550-4W-16
Pre-order
Smoke Extract Roof Fan - RDM 56-4556-4W-17
RDM 56-4556-4W-17
Pre-order
Smoke Extract Roof Fan - RDM 56-5663-4W-23
RDM 56-3545-4W-13
Pre-order
Smoke Extract Roof Fan - RDM 57-2528-2W-11
RDM 57-2528-2W-11
Pre-order
Smoke Extract Roof Fan - RDM 57-2528-4W-10
RDM 57-2528-4W-10
Pre-order
Smoke Extract Roof Fan - RDM 57-3535-4W-10
Pre-order
Smoke Extract Roof Fan - RDM 57-3535-6W-10
Pre-order
Smoke Extract Roof Fan - RDM 57-3540-6W-10
RDM 57-3540-6W-10
Pre-order
Smoke Extract Roof Fan - RDM 57-3545-4W-13
RDM 57-3545-4W-13
Pre-order
Smoke Extract Roof Fan - RDM 57-3545-6W-10
RDM 57-3545-6W-10
Pre-order
Smoke Extract Roof Fan - RDM 57-4550-4W-16
RDM 57-4550-4W-16
Pre-order
Smoke Extract Roof Fan - RDM 57-4550-6W-11
RDM 57-4550-6W-11
Pre-order
Smoke Extract Roof Fan - RDM 57-7180-6W-24
RDM 57-7180-6W-24
Pre-order
Smoke Extract Roof Fan - RWM 57-2528-2W-11
Wall-mounted smoke extract fan rated 600°C/120 min, 2-pole IE2 motor, 2,835 RPM — the highest static pressure capability in the range (~1,000 Pa).
Maximum airflow ~3,500 m³/h, Ø286mm, 1.1 kW / 400V three-phase, 42 kg.
The solution for tunnels with high aerodynamic resistance and long ductwork with multiple bends. Smallest casing in the range.
Certified DIN EN 12101-3, No. 0761-CPR-240031-2.7.
Pre-order
Smoke Extract Roof Fan - RWM 57-2528-4W-10
Wall-mounted smoke extract fan rated 600°C/120 min, 4-pole IE2 motor, 1,440 RPM.
Maximum airflow ~1,800 m³/h, Ø286mm, 0.55 kW / 400V three-phase, 40 kg.
At 73 dB(A) — the quietest model in the RWM range.
The compact solution for buildings with small exhaust cross-sections and strict acoustic requirements.
Certified DIN EN 12101-3, No. 0036-CPR-RG01-17.
Pre-order
Smoke extract wall fan - RWM 57-3540-4W-10
Wall-mounted smoke extract fan certified for operation at 600°C for 120 minutes — the highest fire resistance class available, required in road tunnels, railway tunnels and buildings with extreme fire risk.
Motor completely outside the hot gas zone, cooled by outside air — the key to reliable operation under extreme thermal conditions.
Robust galvanised steel casing, backward curved impeller of welded coated steel.
Certified to DIN EN 12101-3, No. 0036-CPR-RG01-17.
Maximum airflow ~5,000 m³/h, power 0.55 kW / 400V three-phase, weight 62 kg.
Pre-order
Smoke extract wall fan - RWM 57-3540-6W-10
Wall-mounted smoke extract fan rated 600°C/120 min, 6-pole IE2 motor, 925 RPM — the low-noise variant on the Ø395mm casing.
Maximum airflow ~3,500 m³/h, ~240 Pa, 0.37 kW / 400V three-phase, 61 kg, 74 dB(A).
Lower consumption and noise than the 4-pole model on the same casing — the correct choice when moderate airflows and acoustic limits take priority.
Certified DIN EN 12101-3, No. 0036-CPR-RG01-17.
Pre-order
Sales